Friday, November 24, 2017

Contact Brand Master

Gaseous Suppression Systems

Gas fire extinguishing modules of the "Impulse" series - the most popular solution for gas fire suppression systems due to technical advantages and the best price.

Modules are designed for long-term storage under pressure and release into the protected volume of gas extinguishing agents for extinguishing fires of Class A, B, C and electrical equipment under voltage.

Gas fire extinguishing modules of the "Impulse" series are used as part of automatic fire extinguishing systems and as an autonomous fire-extinguishing system.

The modules are filled with fire-extinguishing agents HFC-125, HFC-227ea, FK-5-1-12. The weight of the refueling depends on the volume of the protected room, combustible substances, the temperature in the protected room and is calculated in accordance with EN 15004, NFPA 2001, ISO 14520.

Modules can be mounted on a ceiling or wall (defined by the project on the system). Impulse-2-T and Impulse-20-T modules use a valve with an outlet branch pipe, to which a high-pressure hose with a nozzle is connected.

APPLICATION AREA

ADVANTAGE

  • server rooms;
  • data processing centers (data centers);
  • mobile communication stations;
  • switching;
  • archives;
  • depositories;
  • engine rooms of elevators;
  • museums;
  • UPS room;
  • no hydraulic calculations are required at the design stage;
  • reduction of expenses for equipment, materials and works on installation of the distribution pipeline;
  • due to the design, there is no residual extinguishing agent in the module and the pipeline;
  • do not occupy a useful space in the protected room;
  • when applying "Module Impulse-2-T" and "Module Impulse-20-T", it is possible to supply gas extinguishing agents to enclosed volumes (raised floor, false ceilings, cold corridors, cabinets, etc.).
  • automatic and autonomous system start-up is provided;

MODULE IMPULSE-2 (25-2,2-18)

MODULE IMPULSE-2

The scope of application is the volumes under the raised floor, behind the false ceiling, the protection of server cabinets, electrical cabinets with the possibility of placing modules within the protected volume.

Read more ...

MODULE IMPULSE-20 (25-22,5-18)

MODULE IMPULSE-20

They are used for fire protection of volumes up to 30 m3. As a rule, small rooms of server rooms, archives, electrical boards, depositories, machine sections of elevators are protected.

Read more ...

MODULE IMPULSE-2-T (25-2,2-18)

Module Impulse-2-T

It is used for fire extinguishing the volume of electrical cabinets, false ceilings, raised floor. Pipe modification module allows you to place the module outside the protected volume and feed the fire extinguishing agent through the hose through the nozzles.

Read more ...

MODULE IMPULSE-20-T (25-22,5-18)

MODULE IMPULSE-20-T

It is used for fire extinguishing the volume of electrical cabinets, false ceilings, raised floor. Pipe modification module allows you to place the module outside the protected volume and feed the fire extinguishing agent through the hose through the nozzles.

Read more ...

OPTIONAL EQUIPMENT

OPTIONAL EQUIPMENT

Optional equipment for the modules "Impulse-2-T" and "Impulse-20-T" includes a high-pressure hose type "PBT" and a nozzle type "HP".

Read more ...